I-Encephalitis B Virus Nucleic Acid

Incazelo emfushane:

Le khithi isetshenziselwa ukuthola igciwane le-encephalitis B elisezingeni eliphezulu ku-serum kanye ne-plasma yeziguli ezisebenzisa i-vitro.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

Ikhithi Yokuthola I-Nucleic Acid Ye-HWTS-FE003-Encephalitis B Virus (i-Fluorescence PCR)

I-Epidemiology

I-encephalitis yaseJapan iyisifo esithathelwanayo esithwalwa igazi, esiyingozi kakhulu empilweni nasekuphileni kweziguli. Ngemva kokuba umuntu etheleleke ngegciwane le-encephalitis B, ngemva kwezinsuku ezi-4 kuya kwezi-7 zokufukamela, inani elikhulu lamagciwane liyasakazeka emzimbeni, futhi igciwane lisakazeka emangqamuzaneni esibindini, e-spleen, njll. Ebangeni elincane leziguli (0.1%), igciwane emzimbeni lingabangela ukuvuvukala kwama-meninges kanye nezicubu zobuchopho. Ngakho-ke, ukuxilongwa okusheshayo kwegciwane le-encephalitis B kuyisihluthulelo sokwelashwa kwe-encephalitis yaseJapan, futhi ukusungulwa kwendlela yokuxilonga elula, eqondile nesheshayo kubaluleke kakhulu ekuxilongweni kwe-encephalitis yaseJapan emtholampilo.

Amapharamitha Obuchwepheshe

Isitoreji

-18℃

Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-9
Uhlobo Lwesifanekiso amasampula e-serum, plasma
CV ≤5.0%
I-LoD Amakhophi angu-2000/mL
Izinsimbi Ezisebenzayo Kusebenza ku-reagent yokuthola uhlobo I:Izinhlelo ze-PCR ze-Applied Biosystems 7500 Real-Time,I-QuantStudio®Izinhlelo ze-PCR zesikhathi sangempela ezi-5,

Izinhlelo ze-PCR ze-SLAN-96P Zesikhathi Sangempela (i-Hongshi Medical Technology Co., Ltd.),

Izinhlelo Zokuthola i-LineGene 9600 Plus Real-Time PCR (FQD-96A,Ubuchwepheshe be-Hangzhou Bioer),

I-MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

Uhlelo lwe-BioRad CFX96 lwe-Real-Time PCR,

Uhlelo lwe-BioRad CFX Opus 96 lwe-Real-Time PCR.

Kusebenza ku-reagent yokuthola uhlobo lwesibili:

I-EudemonTMI-AIO800 (HWTS-EQ007) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ukugeleza Komsebenzi

I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor Document No.:HWTS-STP-IFU-JEV Catalog Number: HWTS-FE003A (HWTS-3006C, HWTS-3006B)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhipha kufanele kuqalwe ngokuya nge-IFU ye-reagent yokukhipha. Ivolumu yesampula ekhishwe ingu-200μL kanti ivolumu yokulungisa enconywayo ingu-80 μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi