Iqembu B Streptococcus Nucleic Acid

Incazelo emfushane:

Le kit isetshenziselwa ukuthola ngokufanelekile i-group B streptococcus nucleic acid DNA in vitro rectal swabs, i-swabs yesitho sangasese sowesifazane noma i-rectal/vagin swabs yabesifazane abakhulelwe abanezici eziyingozi kakhulu emasontweni angama-35 ~ 37 okukhulelwa, namanye amasonto okukhulelwa anezimpawu zomtholampilo ezifana njengokuqhekeka kolwelwesi ngaphambi kwesikhathi, usongo lokuzala ngaphambi kwesikhathi, njll.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-UR027-Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)
I-HWTS-UR028-Freeze-dried Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)

Isitifiketi

CE, FDA

I-Epidemiology

I-Group B Streptococcus (GBS), eyaziwa nangokuthi i-streptococcus agalactiae, iyigciwane lesandulela ngculazi elithola ithuba elivamile elihlala emapheshaneni aphansi amathumbu kanye ne-urogenital yomzimba womuntu.Cishe i-10% -30 % yabesifazane abakhulelwe bane-GBS yokuvakasha kwangasese.

Abesifazane abakhulelwe basengozini yokutheleleka nge-GBS ngenxa yoshintsho endaweni yangaphakathi yomgudu wokuzala ngenxa yezinguquko emazingeni ama-hormone emzimbeni, okuzodala imiphumela emibi yokukhulelwa njengokubeletha ngaphambi kwesikhathi, ukuphuka ngaphambi kwesikhathi kolwelwesi, kanye nokubeletha, futhi kungase futhi kubangele imiphumela emibi yokukhulelwa. kuholela ezifweni zokuzala kwabesifazane abakhulelwe.

I-Streptococcus yeqembu lezingane ezisanda kuzalwa ihlotshaniswa ne-perinatal infection futhi iyigciwane elibalulekile lezifo ezithathelwanayo ezinzima njenge-neonatal sepsis kanye ne-meningitis.U-40% -70% womama abangenwe yi-GBS bazodlulisela i-GBS ezinganeni zabo ezisanda kuzalwa ngesikhathi sokubeletha ngomgudu wokuzalwa, okubangela izifo ezithathelwanayo ezithinta izingane ezisanda kuzalwa njenge-neonatal sepsis kanye ne-meningitis.Uma izingane ezisanda kuzalwa ziphethe i-GBS, cishe i-1% -3% izoba nezifo ezihlasela ngokushesha, lapho u-5% wazo uzoholela ekufeni.

Isiteshi

FAM Ithagethi ye-GBS
VIC/HEX Ukulawula kwangaphakathi

Imingcele Yezobuchwepheshe

Isitoreji Uketshezi: ≤-18℃ ebumnyameni;I-Lyophilization: ≤30℃ ebumnyameni
Impilo yeshelufu Izinyanga ezingu-12
Uhlobo lwesifanekiso Izimfihlo zesitho sangasese kanye namaRectal
Ct ≤38
CV ≤5.0%
LoD 1×103Amakhophi/mL
Ukumboza ama-Subtypes Thola i-group B streptococcus serotypes (I a, I b, I c, II, III, IV, V, VI, VII, VIII, IX kanye ne-ND) futhi imiphumela yonke ilungile.
Ukucaciswa Thola amanye amasampula ezitho zangasese kanye ne-rectal swab efana ne-candida albicans, i-trichomonas vaginalis, i-chlamydia trachomatis, ureaplasma urealyticum, i-neisseria gonorrhoeae, i-mycoplasma hominis, i-mycoplasma genitalium, i-herpes simplex virus, i-herpes simplex virus, i-human papilloma virus, i-national papilloma virus, i-lactocusnagathi ye-status, i-lactocusnagathi ye-status I-N1-N10 (i-streptococcus pneumoniae, i-streptococcus pyogenes, i-streptococcus thermophilus, i-streptococcus mutans, i-streptococcus pyogenes, i-lactobacillus acidophilus bacillus, i-lactobacillus reuteri, i-escherichia coli DH5αs, imiphumela ye-DNA ye-gebicanstre yabantu ne-gebicanstre ye-gebicanstre yabantu bonke.
Izinsimbi Ezisebenzayo Ingakwazi ukufanisa amathuluzi we-PCR we-fluorescent avamile emakethe.
SLAN-96P Real-Time PCR Systems
I-ABI 7500 Real-Time PCR Systems
I-QuantStudio®5 Real-Time PCR Systems
I-LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
I-MA-6000 Real-Time Quantitative Thermal Cycler

Isixazululo se-PCR esiphelele

Phrinta
Iqembu B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)7

  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona