I-HPV16 kanye ne-HPV18

Incazelo emfushane:

Le kit is intened for the in vitro qualitative discovery of specific nucleic acid piece of human papillomavirus (HPV) 16 and HPV18 in vitro exfoliated cell cell.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

HWTS-CC001-I-HPV16 kanye ne-HPV18 Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Umdlavuza womlomo wesibeletho ungesinye sezimila eziyingozi ezivame kakhulu emgudwini wokuzala wabesifazane.Kukhonjisiwe ukuthi ukutheleleka nge-HPV okungapheli kanye nezifo eziningi kungenye yezimbangela ezinkulu zomdlavuza womlomo wesibeletho.Okwamanje kusenokuntuleka kwemithi yokwelapha esebenzayo eyamukelekayo yomdlavuza womlomo wesibeletho obangelwa i-HPV.Ngakho-ke, ukutholakala kusenesikhathi kanye nokuvimbela ukutheleleka komlomo wesibeletho okubangelwa i-HPV yizihluthulelo zokuvimbela umdlavuza womlomo wesibeletho.Ukusungulwa kwezivivinyo ezilula, eziqondile nezisheshayo zokuxilonga amagciwane kubaluleke kakhulu ekuhlonzweni komtholampilo komdlavuza womlomo wesibeletho.

Isiteshi

Isiteshi Uhlobo
FAM I-HPV18
VIC/HEX I-HPV16
CY5

Ukulawula Kwangaphakathi

Imingcele Yezobuchwepheshe

Isitoreji

≤-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso iseli yomlomo wesibeletho exfoliated
Ct ≤28
CV ≤10.0%
LoD 500 Amakhophi/mL
Ukucaciswa Uma usebenzisa ikhithi ukuhlola izibonelo ezingaqondile ezingase zisabele kulokho okuhlosiwe, yonke imiphumela iba mibi, okuhlanganisa i-Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mildew, Gardnerella kanye nezinye izinhlobo ze-HPV ezingamboziwe. ikhithi.
Izinsimbi Ezisebenzayo I-SLAN®-96P Real-Time PCR SystemsI-Applied Biosystems 7500 Real-Time PCR Systems

I-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela

I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela

I-LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, ubuchwepheshe be-Hangzhou Bioer)

I-MA-6000 Real-Time Quantitative Thermal Cycler.

Ukugeleza komsebenzi

Inketho1.

I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), kufanele ikhishwe ngokuya ngemiyalo.

Inketho2.

I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS-3006C), kufanele ikhishwe ngokulandela imiyalelo.Ivolumu yesampula ekhishiwe ingu-200μL, futhi ivolumu ye-elution enconyiwe ingu-80µL.

Inketho3.

I-QIAamp DNA Mini Kit (51304) ekhiqizwe i-QIAGEN noma i-TIANamp Virus DNA/RNA Kit (YDP315) ekhiqizwa yi-Tiangen Biotech (Beijing) Co., Ltd., kufanele ikhishwe ngokuhambisana neziyalezo eziqinile.Ivolumu yesampula ekhishiwe ingu-200μL, futhi ivolumu ye-elution enconyiwe ingu-80µL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona