Ikhithi ye-RT-time ye-Fluorescent RT-PCR yokuthola i-SARS-CoV-2

Incazelo emfushane:

Le khithi ihloselwe ukuthola kahle i-orf1ab nezakhi zofuzo ze-coronavirus (SARS-cov-2) kwi-nasopharyngellielale swab kanye ne-oropharyngelling swab eqoqwe nge-pneumonia yenoveli kanye nabanye okutholakele noma ukuxilongwa okuhlukile kokutheleleka kwe-coronavirus anoveli.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

I-HWTS-RT057A-real-time fluorescent rt-pcr kit ukuthola i-SARS-CoV-2

I-HWTS-RT057FF-IQHAWULEKI KOKUGCINA KWESIKHATHI SAMAHHALA SAMEMO SAMAHHALA WOKUTHOLA ISARS-CoV-2 -SUBPatage

Isitifiketi

CE

I-Epidemiology

I-coronavirus yenoveli (SARS-Cov-2) isabalale ngezinga elikhulu emhlabeni jikelele. Enqubweni yokusabalalisa, ukuguqulwa okusha kwenzeka njalo, okuholela ekuhlukaneni okusha. Lo mkhiqizo usetshenziselwa ukutholwa okusizayo kanye nokwehlukanisa amacala ahlobene nokutheleleka ngemuva kokusakazeka okukhulu kwe-alpha, beta, i-gamma, delta kanye nezinkinga ze-omicron mutant kusukela ngoDisemba 2020.

Insungubezi

-Yenza U-2019-NCOV Orf1ab gene
Cy5 Ngo-2019-NCOV N Gene
I-VIC (Hex) Uhlobo lwangaphakathi lwereferensi

Amapharamitha Ezobuchwepheshe

Ukubeka

Uketshezi: ≤-18 ℃ ebumnyameni

I-Lyophile: ≤30 ℃ ebumnyameni

Ishalofu-impilo

Uketshezi: izinyanga eziyi-9

I-Lyophilised: Izinyanga eziyi-12

Uhlobo lwe-Specimen

I-Nasopharyngel Swabs, i-Oropharyngengeal Swabs

CV

≤5.0%

Ct

≤38

Indlu edayisa insimbi

300copies / ml

Ukucacisa

Akukho okuphambana nokusebenzisa imali ngama-coronaviveses womuntu sarS-CoV namanye amagciwane ajwayelekile.

Izinsimbi ezisebenzayo:

Kusetshenziswe ama-biosystems 7500 real-time PCREMS

Kusetshenziswe ama-biosystem 7500 ngokushesha amasistimu we-real-time PCR

SLAN ®-96P real-time PCRS Systems

I-QuantStudio ™ 5 Izinhlelo ze-PCR zangempela zesikhathi sangempela

I-Lightcycler®480 Uhlelo lwe-PCR yesikhathi sangempela

I-LineGene 9600 Plus Real-Time Pcc Retection System

I-MA-6000 I-CYRLE YOKUQHAWULA YOKUQALA

I-Biorad CFX96 Uhlelo lwe-Real-Time PCR

Biorad cfx opus 96 uhlelo lwe-real-time PCR

Ukugeleza komsebenzi

Inketho 1.

Ukukhishwa kwe-nucleic acid noma ikhithi yokuhlanza (indlela yobuhlalu ye-magnetic) (HWTS-3001, i-HWTS-3004-32, i-HWS-3004-48) kusuka kuJiangsu Macro & Micro-Test Med-Tech Co, Ltd.

Inketho 2.

I-realent enconyiwe I-realent: I-QAAMP Viral RNA MINI KIT (52904), i-Viral RNA Extraction Kit (yppp35-R) ekhiqizwe yiTiangen Biotech (Beijing) Co, Ltd.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha bese usithumela kithi