I-Treponema Pallidum Nucleic Acid

Incazelo emfushane:

Leli khithi lifanelekela ukutholakala kwe-Treponema Pallidum (TP) esikhumbeni somchamo sabesilisa, isikhumbeni somlomo wesibeletho sabesifazane, kanye namasampula esikhumbeni somchamo sabesifazane, futhi lisiza ekuxilongweni nasekulashweni kweziguli ezinegciwane le-Treponema pallidum.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

Ikhithi Yokuthola I-HWTS-UR047-Treponema Pallidum Nucleic Acid (i-Fluorescence PCR)

I-Epidemiology

I-Syphilis yisifo esivamile esidluliselwa ngocansi emtholampilo, ikakhulukazi sibhekisela esifweni esingamahlalakhona, esidluliselwa ngocansi esibangelwa ukutheleleka kwe-Treponema Pallidum (TP). I-Syphilis isakazeka kakhulu ngokudluliselwa ngocansi, ukudluliselwa kusuka kumama kuya enganeni kanye nokudluliselwa kwegazi. Iziguli ze-Syphilis ziwukuphela komthombo wokutheleleka, kanti i-Treponema pallidum ingaba khona esidodaneni sabo, ubisi lwebele, amathe kanye negazi. I-Syphilis ingahlukaniswa ngezigaba ezintathu ngokuya ngenkambo yesifo. I-Syphilis yesigaba sokuqala ingabonakala njenge-chancre eqinile kanye nama-lymph node avuvukele, ngalesi sikhathi atheleleka kakhulu. I-Syphilis yesigaba sesibili ingabonakala njenge-syphilitic rash, i-hard chancre iyaphela, futhi ukutheleleka nakho kunamandla. I-Syphilis yesigaba sesithathu ingabonakala njenge-syphilis yamathambo, i-neurosyphilis, njll.

Amapharamitha Obuchwepheshe

Isitoreji

-18℃

Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-12
Uhlobo Lwesifanekiso i-swab yesilisa ye-urethra, i-swab yesibeletho yesifazane, i-swab yesitho sangasese sowesifazane
Ct ≤38
CV ≤10.0%
I-LoD Amakhophi angu-400/μL
Izinsimbi Ezisebenzayo Kusebenza ku-reagent yokuthola uhlobo I:

Izinhlelo ze-PCR ze-Applied Biosystems 7500 Real-Time,

I-QuantStudio®Izinhlelo ze-PCR zesikhathi sangempela ezi-5,

Izinhlelo ze-PCR ze-SLAN-96P Zesikhathi Sangempela (i-Hongshi Medical Technology Co., Ltd.),

Izinhlelo Zokuthola i-LineGene 9600 Plus Real-Time PCR (FQD-96A, ubuchwepheshe be-Hangzhou Bioer),

I-MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

Uhlelo lwe-BioRad CFX96 lwe-Real-Time PCR,

Uhlelo lwe-BioRad CFX Opus 96 lwe-Real-Time PCR.

Kusebenza ku-reagent yokuthola uhlobo lwesibili:

I-EudemonTMI-AIO800 (HWTS-EQ007) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ukugeleza Komsebenzi

I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kanye ne-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (engasetshenziswa ne-EudemonTM I-AIO800 (HWTS-EQ007)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Umthamo wesampula okhishwe ungama-200μL kanti umthamo wokulungisa onconywayo ungama-150μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi