I-Treponema Pallidum Nucleic Acid

Incazelo emfushane:

Le kit ifanele ukutholwa kwekhwalithi ye-Treponema Pallidum (TP) ku-swab ye-urethral wesilisa, i-swab yomlomo wesibeletho yowesifazane, namasampula e-vaginal swab wesifazane, futhi inikeza usizo ekuxilongweni nasekwelapheni iziguli ezine-Treponema pallidum infection.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-UR047-Treponema Pallidum Nucleic Acid Detection Kit(Fluorescence PCR)

I-Epidemiology

I-Syphilis yisifo esivamile esithathelwana ngocansi emisebenzini yomtholampilo, ikakhulukazi ibhekisela kusifo esingelapheki, esinesistimu esithathelwana ngocansi esibangelwa ukutheleleka kwe-Treponema Pallidum (TP). I-Syphilis isakazwa kakhulu ngokusulelana ngocansi, ukudluliselwa komama enganeni kanye nokudluliselwa kwegazi. Iziguli ze-Syphilis ziwukuphela komthombo wokutheleleka, futhi i-Treponema pallidum ingaba khona esidodeni sabo, ubisi lwebele, amathe negazi. I-Syphilis ingahlukaniswa izigaba ezintathu ngokuya ngenkambo yesifo. I-syphilis yesigaba sokuqala ingase ibonakale njenge-chancre eqinile kanye nama-lymph nodes angu-inguinal avuvuke, ngalesi sikhathi esithathelwanayo kakhulu. I-syphilis yesigaba sesibili ingase ibonakale njengokuqubuka kwe-syphilitic, i-chancre eqinile iyancipha, futhi ukusuleleka kunamandla. I-syphilis yesigaba semfundo ephakeme ingase ibonakale njenge-bone syphilis, neurosyphilis, njll.

Imingcele Yezobuchwepheshe

Isitoreji

-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso i-wab yowesilisa, i-swab yomlomo wesibeletho yowesifazane, i-swab yesitho sangasese sowesifazane
Ct ≤38
CV ≤10.0%
LoD 400 Amakhophi/μL
Izinsimbi Ezisebenzayo Isebenza ekuthayipheni i-reagent yokuthola i-I:

I-Applied Biosystems 7500 Real-Time PCR Systems,

I-QuantStudio®5 Amasistimu e-PCR wesikhathi sangempela,

I-SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.),

I-LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, ubuchwepheshe be-Hangzhou Bioer),

I-MA-6000 Real-Time Quantitative Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

I-BioRad CFX96 Real-Time PCR System,

I-BioRad CFX Opus 96 Real-Time PCR System.

Isebenza ohlotsheni lwe-II yokutholwa kwe-reagent:

EudemonTMI-AIO800 (HWTS-EQ007) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ukugeleza komsebenzi

I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kanye ne-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-17u-80 esetshenziswa)TM I-AIO800 (HWTS-EQ007)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ivolumu yesampula ekhishiwe ingu-200μL futhi ivolumu ye-lution enconyiwe ingu-150μL.