I-Xinjiang Hemorrhagic Fever Virus

Incazelo emfushane:

Le khithi ivumela ukutholwa kwekhwalithi yegciwane le-Xinjiang hemorrhagic fever nucleic acid kumasampula e-serum yeziguli okusolakala ukuthi ezinomkhuhlane we-Xinjiang hemorrhagic fever, futhi inikeza usizo ekuxilongweni kweziguli ezinomkhuhlane we-Xinjiang hemorrhagic fever.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

HWTS-FE007B/C Xinjiang Hemorrhagic Fever Virus Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Igciwane le-Xinjiang hemorrhagic fever laqala ukuhlukaniswa negazi leziguli ezinemfiva yokopha eTarim Basin, eXinjiang, eChina kanye nemikhaza eqinile ebanjwe endaweni, futhi yaqanjwa igama layo. Ukubonakaliswa kwemitholampilo kuhlanganisa imfiva, ikhanda elibuhlungu, ukopha, ukushaqeka kwe-hypotensive, njll. Izinguquko eziyisisekelo ze-pathological zalesi sifo yi-systemic capillary dilatation, ukuminyana, ukwanda kwe-permeability kanye nokuba ntekenteke, okuholela emazingeni ahlukene okuminyana kanye nokopha esikhumbeni kanye nolwelwesi lwamafinyila kanye nezicubu zezitho ezihlukahlukene emzimbeni wonke, ngokuwohloka kanye ne-necrosis enjalo, i-pillary gland, izitho eziqinile ze-adrenal. i-edema efana ne-jelly ku-retroperitoneum.

Isiteshi

FAM I-Xinjiang Hemorrhagic Fever Virus
I-ROX

Ukulawula Kwangaphakathi

Imingcele Yezobuchwepheshe

Isitoreji

≤-18℃

Impilo yeshelufu 9 izinyanga
Uhlobo Lwesifanekiso i-serum entsha
Tt ≤38
CV 5.0%
LoD 1000Amakhophi/mL
Ukucaciswa

Akukho ukuphinda kusebenze namanye amasampula okuphefumula afana nomkhuhlane A, Umkhuhlane B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3, Coxsackie virus, Echo virus, Metapnevirus A1/A1/A2u syncytial virus A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, njll. kanye ne-DNA yegenomic yomuntu.

Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR Systems,

Applied Biosystems 7500 Fast Real-Time PCR Systems

I-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela

SLAN-96P Real-Time PCR Systems

I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela

LineGene 9600 Plus Real-Time PCR Detection Systems

I-MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Ukugeleza komsebenzi

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ivolumu yesampula ekhishiwe ingu-200µL, futhi ivolumu ye-elution enconyiwe ngu-80µL.

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-QIAamp Viral RNA Mini Kit (52904) nge-QIAGEN kanye ne-Nucleic Acid Extraction noma i-Purification Reagent (YDP315-R). Ukukhishwa kufanele kwenziwe ngokuhambisana ngokuqinile nemiyalelo yokusetshenziswa. Ivolumu yesampula ekhishiwe ingu-140µL, futhi ivolumu ye-elution enconyiwe ngu-60µL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona