I-ALDH Genetic Polymorphism

Incazelo emfushane:

Le khithi isetshenziselwa ukuthola indawo ye-ALDH2 gene G1510A polymorphism ku-DNA ye-genomic yegazi lomuntu engaphandle.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

I-HWTS-GE015Ikhithi Yokuthola I-ALDH Genetic Polymorphism (ARMS -PCR)

I-Epidemiology

I-ALDH2 gene (i-acetaldehyde dehydrogenase 2), itholakala ku-chromosome yomuntu 12. I-ALDH2 ine-esterase, i-dehydrogenase kanye nomsebenzi we-reductase ngesikhathi esifanayo. Izifundo zibonise ukuthi i-ALDH2 iyi-enzyme ye-metabolic ye-nitroglycerin, eguqula i-nitroglycerin ibe yi-nitric oxide, ngaleyo ndlela ikhulule imithambo yegazi futhi ithuthukise ukuphazamiseka kokugeleza kwegazi. Kodwa-ke, kunezinhlobo eziningi ze-enzyme ku-ALDH2 gene, ezigxile kakhulu eMpumalanga Asia. I-ALDH2*1/1 GG yohlobo lwasendle inekhono eliqinile le-metabolic, kuyilapho uhlobo lwe-heterozygous luno-6% kuphela womsebenzi we-enzyme yohlobo lwasendle, kanti uhlobo lwe-homozygous mutant alunawo umsebenzi we-enzyme cishe, kanti i-metabolism ibuthakathaka kakhulu futhi ayikwazi ukufeza umphumela oyifunayo, ngaleyo ndlela ibangele ukulimala emzimbeni womuntu.

Isiteshi

I-FAM I-ALDH2
I-ROX

Ukulawula Kwangaphakathi

Amapharamitha Obuchwepheshe

Isitoreji

≤-18℃

Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-12
Uhlobo Lwesifanekiso Igazi elingasebenzi kahle le-EDTA
CV <5.0%
I-LoD 103Amakhophi/mL
Izinsimbi Ezisebenzayo Uhlelo lwe-PCR lwe-Applied Biosystems 7500 Real-Time

Izinhlelo ze-PCR ze-Applied Biosystems 7500 Fast Real-Time

I-QuantStudio®Izinhlelo ze-PCR zesikhathi sangempela ezi-5

Izinhlelo ze-PCR Zesikhathi Sangempela ze-SLAN-96P

I-LightCycler®Uhlelo lwe-PCR lwesikhathi sangempela lwe-480

Uhlelo Lokuthola i-LineGene 9600 Plus Real-Time PCR

I-MA-6000 Real-Time Quantitative Thermal Cycler

Uhlelo lwe-BioRad CFX96 Real-Time PCR

Uhlelo lwe-BioRad CFX Opus 96 lwe-Real-Time PCR

Ukugeleza Komsebenzi

Ama-reagent okukhipha anconyiwe: sebenzisa i-Blood Genome DNA Extraction Kit (DP318) yi-Tiangen Biotech (Beijing) Co., Ltd. noma i-Blood Genome Extraction Kit (A1120) yi-Promega ukuze ukhiphe i-EDTA yegazi elingasebenzi kahle i-Genomic DNA.

Ama-reagent okukhipha anconyiwe: I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhipha kufanele kwenziwe ngokwemiyalelo ngokuqinile. Ivolumu yokususa enconyiwe ingu100μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi