I-Mycoplasma Genitalium (Mg) Ikhithi Yokuthola I-Acid Yenucleic

Incazelo emfushane:

Le khithi isetshenziselwa ukuthola i-Mycoplasma genitalium (Mg) nucleic acid etholakala ngaphakathi kwe-vitro emgudwini womchamo wabesilisa kanye nokuphuma komgudu wokuzala wabesifazane.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

I-Mycoplasma Genitalium (Mg) Ikhithi Yokuthola I-Acid Yenucleic

I-Epidemiology

Izifo ezithathelwana ngocansi (STD) zisalokhu zingenye yezinsongo ezinkulu ekuphepheni kwempilo yomphakathi emhlabeni wonke, okungaholela ekungazalini, ekuzalweni ngaphambi kwesikhathi, ekuveleni kwe-tumor, kanye nezinkinga eziningi ezinkulu [1-4]. Kunezinhlobo eziningi zezifo ezithathelwana ngocansi, okuhlanganisa amagciwane, amagciwane, i-chlamydia, i-mycoplasma, kanye nama-spirochetes. Izinhlobo ezivamile zifaka phakathi i-Neisseria gonorrhoeae, i-Chlamydia trachomatis, i-Ureaplasma urealyticum, i-Herpes simplex virus type 1, i-Herpes simplex virus type 2, i-Mycoplasma hominis, i-Mycoplasma genitalium kanye nokunye.

Isiteshi

I-FAM Mg
I-ROX

Ukulawula Kwangaphakathi

Amapharamitha Obuchwepheshe

Isitoreji

-18℃

Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-12
Uhlobo Lwesifanekiso uukukhishwa kwe-rethral,ukukhiqizwa komlomo wesibeletho
Tt ≤38
CV ≤5.0%
I-LoD Amakhophi angu-500/μL
Ukucaciswa Akukho ukuhlangana kwezifo ezithathelwana ngocansi nezinye izifo ezithathelwana ngocansi, njenge-Chlamydia trachomatis, i-Ureaplasma urealyticum, i-Neisseria gonorrhoeae, i-Mycoplasma hominis, i-Herpes simplex virus type 1, kanye ne-Herpes simplex virus type 2.
Izinsimbi Ezisebenzayo Izinhlelo ze-PCR ze-Applied Biosystems 7500 Real-TimeI-QuantStudio®Izinhlelo ze-PCR zesikhathi sangempela ezi-5

Izinhlelo ze-PCR Zesikhathi Sangempela ze-SLAN-96P

I-LightCycler®Uhlelo lwe-PCR lwesikhathi sangempela lwe-480

Uhlelo Lokuthola i-LineGene 9600 Plus Real-Time PCR

I-MA-6000 Real-Time Quantitative Thermal Cycler

Uhlelo lwe-BioRad CFX96 Real-Time PCR

Uhlelo lwe-BioRad CFX Opus 96 lwe-Real-Time PCR

Ukuhamba komsebenzi

I-Mycoplasma Genitalium (Mg) Ikhithi Yokuthola I-Acid Yenucleic

Ama-reagent adinga kodwa awanikezwa

I-saline evamile, i-Macro kanye ne-Micro-Test Sample Release Release Reagent (HWTS-3005-8), i-Macro kanye ne-Micro-Test General DNA/RNA Kit (HWTS-3017) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B), i-Nucleic Acid Extraction noma i-Purification Reagent (YDP302) yi-Tiangen Biotech (Beijing) Co., Ltd.

Izinto ezisetshenziswayo ziyadingeka kodwa azinikezwa

Amashubhu e-centrifuge angenawo i-DNase/RNase angama-1.5 mL, amathiphu angenawo i-DNase/RNase, imichilo yamashubhu ayi-8 ye-PCR, i-pipette, i-desktop centrifuge, i-desktop oscillation mixer.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi