I-Mycoplasma Genitalium (Mg)

Incazelo emfushane:

Le kit isetshenziselwa ukutholwa kwe-in vitro qualitative ye-Mycoplasma genitalium (Mg) nucleic acid emgudwini womchamo wabesilisa kanye nokuphuma kwepheshana lesitho sangasese sowesifazane.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

HWTS-UR014A Mycoplasma Genitalium (Mg) Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Izifo ezithathelwana ngocansi (STD) zihlala zingenye yezinsongo ezinkulu ekuvikelekeni kwezempilo yomphakathi emhlabeni wonke, okungaholela ekungazali, ukuzalwa ngaphambi kwesikhathi, i-tumorigenesis, kanye nezinkinga ezihlukahlukene ezinzima [1-4].Kunezinhlobo eziningi zamagciwane e-STD, okuhlanganisa amagciwane, amagciwane, i-chlamydia, i-mycoplasma, nama-spirochetes.Izinhlobo ezijwayelekile zihlanganisa i-Neisseria gonorrhoeae, i-Chlamydia trachomatis, i-Ureaplasma urealyticum, i-Herpes simplex virus type 1, i-Herpes simplex virus type 2, i-Mycoplasma hominis, i-Mycoplasma genitalium nokunye.

Isiteshi

FAM Mg
I-ROX

Ukulawula Kwangaphakathi

Imingcele Yezobuchwepheshe

Isitoreji

-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso uukukhishwa kwe-rethral,izimfihlo zomlomo wesibeletho
Tt ≤38
CV ≤5.0%
LoD 500 Amakhophi/μL
Ukucaciswa Akukho ukuhlangana kabusha namanye amagciwane ezifo ezithathelwana ngocansi, njenge-Chlamydia trachomatis, i-Ureaplasma urealyticum, i-Neisseria gonorrhoeae, i-Mycoplasma hominis, i-Herpes simplex virus uhlobo 1, kanye nohlobo 2 lwe-Herpes simplex virus.
Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR SystemsI-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela

SLAN-96P Real-Time PCR Systems

I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela

I-LineGene 9600 Plus Real-Time PCR Detection System

I-MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Ukugeleza komsebenzi

Inketho 1.

I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), kufanele ikhishwengokuqinilengokwemiyalelo.

Inketho yesi-2.

I-Macro&Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS -3006C), kufanele ikhishwe ngokuqinile ngokwemiyalelo.Ivolumu ye-elution enconyiwe ngu-80µL.

Inketho3.

I-Nucleic Acid Extraction noma Ikhithi Yokuhlanza(YDP302)ekhiqizwe i-Tiangen Biotech (Beijing) Co., Ltd., kufanele ikhishwe ngokuhambisana ngokuqinile nemiyalelo.Ivolumu ye-elution enconyiwe ngu-80µL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona