I-Seven Urogenital Pathogen
Igama lomkhiqizo
I-HWTS-UR017A Seven Urogenital Pathogen Nucleic Acid Detection Kit(Melting Curve)
I-Epidemiology
Izifo ezithathelwana ngocansi (STDs) zisengenye yezinsongo ezibalulekile ekuvikelekeni kwezempilo yomphakathi emhlabeni jikelele, ezingaholela ekungazali, ukuzalwa ngaphambi kwesikhathi, izimila kanye nezinkinga ezinzima ezihlukahlukene.Amagciwane avamile ahlanganisa i-chlamydia trachomatis, i-neisseria gonorrhoeae, i-mycoplasma genitalium, i-mycoplasma hominis, i-herpes simplex virus type 2, i-ureaplasma parvum, ne-ureaplasma urealyticum.
Isiteshi
FAM | CT kanye NG |
I-HEX | MG, MH kanye ne-HSV2 |
I-ROX | Ukulawula Kwangaphakathi |
Imingcele Yezobuchwepheshe
Isitoreji | ≤-18℃ |
Impilo yeshelufu | Izinyanga ezingu-12 |
Uhlobo Lwesifanekiso | ukukhishwa kwe-urethra Izimfihlo zomlomo wesibeletho |
Tt | ≤28 |
CV | ≤5.0% |
LoD | CT:500Amakhophi/mL NG:400Amakhophi/mL MG:1000Amakhophi/mL MH:1000Amakhophi/mL HSV2:400Amakhophi/mL UKUZE:500Amakhophi/mL UU:500Amakhophi/mL |
Ukucaciswa | Hlola amagciwane athelelekile ngaphandle kwebanga lokuhlonza lekhithi yokuhlola, njenge-treponema pallidum, i-candida albicans, i-trichomonas vaginalis, i-staphylococcus epidermidis, i-escherichia coli, i-gardnerella vaginalis, i-adenovirus, i-cytomegalovirus, i-beta Streptoctobacillus, i-HIV, i-HIV, i-HIV, i-adenovirus.Futhi akukho-cross-reactivity. Ikhono lokulwa nokuphazamiseka: 0.2 mg/mL bilirubin, amafinyila omlomo wesibeletho, 106amaseli/mL amaseli egazi amhlophe, 60 mg/mL mucin, igazi eliphelele, isidoda, izidakamizwa ezivame ukusetshenziswa ezilwa nefungal (200 mg/mL levofloxacin, 300 mg/mL erythromycin, 500 mg/mL penicillin, 300mg/mL azithromycin, 10% Jieeryin lotion , 5% i-Fuyanjie lotion) ayiphazamisi ikhithi. |
Izinsimbi Ezisebenzayo | SLAN-96P Real-Time PCR Systems Uhlelo lwe-PCR lwe-LightCycler®480 Real-Time |
Ukugeleza komsebenzi
I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).
A) Indlela eyenziwa mathupha: Thatha ishubhu ye-centrifuge engu-1.5mL DNase/RNase-free bese wengeza u-200μL wesampula ezohlolwa.Izinyathelo ezilandelayo kufanele zikhishwe ngokuhambisana ngokuqinile ne-IFU.Ivolumu ye-elution enconyiwe ngu-80μL.
B) Indlela ezenzakalelayo: Thatha ikhithi yokukhipha epakishwe ngaphambili, engeza u-200 μL wesampula ukuze ihlolwe endaweni ehambisanayo yomthombo, futhi izinyathelo ezilandelayo kufanele zikhishwe ngokuhambisana ngokuqinile ne-IFU.