Izinhlobo eziyi-12 zePathogen yokuphefumula

Incazelo emfushane:

Le khithi isetshenziselwa ukutholwa okuhlanganisiwe kwekhwalithi ye-SARS-CoV-2, igciwane lomkhuhlane A, igciwane lomkhuhlane B, i-adenovirus, i-mycoplasma pneumoniae, i-rhinovirus, i-respiratory syncytial virus kanye ne-parainfluenza virus (Ⅰ, II, III, IV) kanye ne-metapneumovirus yabantu i-oropharyngeal swabs.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-RT071A 12 Izinhlobo ze-Respiratory Pathogen Nucleic Acid Detection Kit (Fluorescence PCR)

Isiteshi

Isiteshi awu12Isivimbeli sokusabela A awu12Isivimbeli sokusabela B awu12Isivimbeli sokusabela C awu12Isivimbeli sokusabela D
FAM I-SARS-CoV-2 I-HADV I-HPIV Ⅰ HRV
VIC/HEX Ukulawula Kwangaphakathi Ukulawula Kwangaphakathi I-HPIV Ⅱ Ukulawula Kwangaphakathi
CY5 IFV A MP I-HPIV Ⅲ /
I-ROX IFV B I-RSV I-HPIV Ⅳ I-HMPV

Imingcele Yezobuchwepheshe

Isitoreji

≤-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso I-Oropharyngeal swab
Ct ≤38
CV ≤5.0%
LoD I-SARS-CoV-2:300 Amakhophi/mLigciwane lomkhuhlane B:500 Amakhophi/mLigciwane lomkhuhlane A:500 Amakhophi/mL

I-Adenovirus: Amakhophi angama-500/mL

i-mycoplasma pneumoniae: Amakhophi angu-500/mL

igciwane lokuphefumula syncytial: 500 Amakhophi/mL,

igciwane le-parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ):500 Amakhophi/mL

I-Rhinovirus: Amakhophi angu-500/mL

I-metapneumovirus yomuntu: Amakhophi angama-500/mL

Ukucaciswa Ucwaningo lwe-cross-reactivity lubonisa ukuthi akukho-reactivity phakathi kwaleli kit kanye ne-enterovirus A, B, C, D, igciwane le-epstein-barr, igciwane lesimungumungwane, i-cytomegalovirus yabantu, i-rotavirus, i-norovirus, i-mumps virus, i-varicella-herpes zoster virus, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans kanye human genomic nucleic acid.
Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR SystemsApplied Biosystems 7500 Fast Real-Time PCR SystemsI-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela

I-SLAN-96P Real-Time PCR Systems(Hongshi Medical Technology Co., Ltd.)

I-LightCycler®480 uhlelo lwe-PCR lwesikhathi sangempela,

I-LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, ubuchwepheshe be-Hangzhou Bioer)

I-MA-6000 Real-Time Quantitative Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Ukugeleza komsebenzi

Inketho 1.

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ukukhishwa kufanele kwenziwe ngokuhambisana ngokuqinile nemiyalelo.

 Inketho yesi-2.

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor ( HWTS-3006C, HWTS-3006B) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., ukukhishwa kufanele kwenziwe ngokulandela imiyalelo ngokuqinile.Ivolumu ye-elution enconyiwe ngu-80μL.

 Inketho yesi-3.

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-Nucleic Acid Extraction noma Ikhithi Yokuhlanza (YDP315) yi-Tiangen Biotech(Beijing) Co., Ltd., ukukhipha kufanele kwenziwe ngokulandela imiyalelo ngokuqinile.Ivolumu ye-elution enconyiwe ngu-100μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona