Izinhlobo ezingama-28 ze-Human Papilloma Virus (16/18 Typing) esengozini enkulu ye-Nucleic Acid

Incazelo emfushane:

Le kit ilungele ukutholwa kwe-in vitro qualitative yezinhlobo ezingama-28 zama-human papilloma virus (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) i-nucleic acid kumchamo wesilisa / wesifazane kanye namaseli e-exfoliated yomlomo wesibeletho wesifazane.I-HPV 16/18 ingabhalwa ngomshini, izinhlobo ezisele azikwazi ukuthayipha ngokuphelele, okuhlinzeka ngezindlela ezisizayo zokuxilonga nokwelashwa kokutheleleka nge-HPV.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-CC006A-28 Izinhlobo Zegciwane Le-Human Papilloma Virus (16/18 Typing) I-Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Umdlavuza womlomo wesibeletho ungesinye sezimila eziyingozi ezivame kakhulu emgudwini wokuzala wabesifazane.Ucwaningo luye lwabonisa ukuthi izifo ezihlala njalo ze-HPV kanye nezifo eziningi zingenye yezimbangela eziyinhloko zomdlavuza womlomo wesibeletho.Njengamanje, izindlela zokwelapha ezisebenzayo ezibonwayo azikatholakali umdlavuza womlomo wesibeletho obangelwa i-HPV, ngakho ukutholakala kusenesikhathi kanye nokuvinjelwa kokutheleleka komlomo wesibeletho okubangelwa yi-HPV kuwukhiye wokuvimbela umdlavuza womlomo wesibeletho.Kubaluleke kakhulu ukusungula isivivinyo sokuxilonga i-etiology elula, eqondile futhi esheshayo ukuze kuhlonzwe umtholampilo kanye nokwelashwa komdlavuza womlomo wesibeletho.

Isiteshi

Ukusabela Mix Isiteshi Uhlobo
I-PCR-Mix1 FAM 18
I-VIC(HEX) 16
I-ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Ukulawula Kwangaphakathi
I-PCR-Mix2 FAM 6, 11, 54, 83
I-VIC(HEX) 26, 44, 61, 81
I-ROX 40, 42, 43, 53, 73, 82
CY5 Ukulawula Kwangaphakathi

Imingcele Yezobuchwepheshe

Isitoreji Uketshezi: ≤-18℃
Impilo yeshelufu Izinyanga ezingu-12
Uhlobo lwesifanekiso I-Cervical Swab, I-Vaginal Swab, Umchamo
Ct ≤28
CV <5.0%
LoD 300Amakhophi/mL
Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR Systems
Applied Biosystems 7500 Fast Real-Time PCR Systems
I-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela
SLAN-96P Real-Time PCR Systems
I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela
I-LineGene 9600 Plus Real-Time PCR Detection System
I-MA-6000 Real-Time Quantitative Thermal Cycler
I-BioRad CFX96 Real-Time PCR System
I-BioRad CFX Opus 96 Real-Time PCR System

Ukugeleza komsebenzi

Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (engasetshenziswa ne-Macro & Micro-Test I-Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) nge-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Engeza u-200μL wosawoti ojwayelekile ukuze umise okwesikhashana i-pellet esinyathelweni sesi-2.1, bese ukukhishwa kufanele kwenziwe ngokuvumelana emiyalweni yokusetshenziswa kwalesi sici sokukhipha.Ivolumu ye-elution enconyiwe ngu-80μL.
Isisetshenziswa esisebenzayo sokukhipha esinconyiwe: I-QIAamp DNA Mini Kit (51304) noma i-Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Engeza u-200μL we-saline evamile ukuze umise kabusha i-pellet esinyathelweni sesi-2.1, bese ukukhishwa kufanele kwenziwe ngokuvumelana nemiyalelo yokusetshenziswa kwalesi sici sokukhipha.Ivolumu yesampula ekhishiwe yamasampula wonke angu-200μL, futhi ivolumu ye-elution enconyiwe ingu-100μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona