Izinhlobo ezingu-28 ze-Human Papilloma Virus eyingozi kakhulu (uhlobo lwe-16/18) i-Nucleic Acid

Incazelo emfushane:

Izitifiketi: CE, Vietnam MDA, TFDA, AMMPS

Le khithi ifanelekela ukutholwa kwezinhlobo ezingu-28 zamagciwane e-human papilloma (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) ze-nucleic acid kumchamo wesilisa/wesifazane kanye namaseli akhishwe esibelethweni sowesifazane. I-HPV 16/18 ingabhalwa nge-in vitro, izinhlobo ezisele azikwazi ukubhalwa nge-in vitro, okuhlinzeka ngemithi yokusiza yokuxilongwa nokwelashwa kokutheleleka kwe-HPV.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

Izinhlobo ze-HWTS-CC006A-28 ze-Human Papilloma Virus eyingozi kakhulu (16/18 Typing) I-Nucleic Acid Detection Kit (i-Fluorescence PCR)

I-Epidemiology

Umdlavuza womlomo wesibeletho ungenye yezimila eziyingozi ezivame kakhulu ohlelweni lokuzala lwabesifazane. Izifundo zikhombisile ukuthi ukutheleleka okuqhubekayo kwe-HPV kanye nokutheleleka okuningi kungenye yezimbangela eziyinhloko zomdlavuza womlomo wesibeletho. Njengamanje, ukwelashwa okusebenzayo okuqashelwayo kusantuleka komdlavuza womlomo wesibeletho obangelwa yi-HPV, ngakho-ke ukutholakala kusenesikhathi nokuvimbela ukutheleleka komlomo wesibeletho okubangelwa yi-HPV kuyisihluthulelo sokuvimbela umdlavuza womlomo wesibeletho. Kubaluleke kakhulu ukusungula isivivinyo sokuxilonga esilula, esiqondile nesisheshayo se-etiology sokuxilongwa kanye nokwelashwa komdlavuza womlomo wesibeletho.

Isiteshi

Ingxube Yokusabela Isiteshi Uhlobo
I-PCR-Mix1 I-FAM 18
I-VIC(HEX) 16
I-ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Ukulawula Kwangaphakathi
I-PCR-Mix2 I-FAM 6, 11, 54, 83
I-VIC(HEX) 26, 44, 61, 81
I-ROX 40, 42, 43, 53, 73, 82
CY5 Ukulawula Kwangaphakathi

Amapharamitha Obuchwepheshe

Isitoreji Uketshezi: ≤-18℃
Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-12
Uhlobo Lwesifanekiso I-Swab Yesibeletho, I-Swab Yesitho Sangasese Sowesifazane, Umchamo
Ct ≤28
CV <5.0%
I-LoD Amakhophi angu-300/mL
Izinsimbi Ezisebenzayo Izinhlelo ze-PCR ze-Applied Biosystems 7500 Real-Time
Izinhlelo ze-PCR ze-Applied Biosystems 7500 Fast Real-Time
I-QuantStudio®Izinhlelo ze-PCR zesikhathi sangempela ezi-5
Izinhlelo ze-PCR Zesikhathi Sangempela ze-SLAN-96P
I-LightCycler®Uhlelo lwe-PCR lwesikhathi sangempela lwe-480
Uhlelo Lokuthola i-LineGene 9600 Plus Real-Time PCR
I-MA-6000 Real-Time Quantitative Thermal Cycler
Uhlelo lwe-BioRad CFX96 Real-Time PCR
Uhlelo lwe-BioRad CFX Opus 96 lwe-Real-Time PCR

Ukugeleza Komsebenzi

Bheka i-Kit IFU ukuthola imininingwane

Isixazululo 1 (Ukukhishwa kwe-nucleic acid okuzenzakalelayo)

Bheka i-Kit IFU ukuthola imininingwane1

Isixazululo 2: (I-Macro & Micro-Test Sample Release Release Reagent)

Bheka i-Kit IFU ukuthola imininingwane2

Ama-reagent adinga kodwa awanikezwa

I-Macro & Micro-Test Sample Release Release Reagent (HWTS-3005-8), I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ikholomu ye-Macro & Micro-Test Viral DNA/RNA (HWTS-3020-50).

Izinto ezisetshenziswayo ziyadingeka kodwa azinikezwa

Amashubhu e-centrifuge angenayo i-DNase/RNase angu-1.5mL, Amathiphu angenayo i-DNase/RNase, amashubhu e-PCR angu-0.2mL, i-desktop centrifuge, i-desktop oscillation mixer.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi