I-Gardnerella Vaginalis Nucleic Acid
Igama lomkhiqizo
I-HWTS-UR042-Gardnerella Vaginalis Nucleic Acid Detection Kit(Fluorescence PCR)
I-Epidemiology
Isizathu esivame kakhulu se-vaginitis kwabesifazane i-bacterial vaginosis, futhi i-bacterial pathogenic bacterium ye-bacterial vaginosis yi-Gardnerella vaginalis. I-Gardnerella vaginalis (GV) iyigciwane lesandulela ngculaza elingosomathuba elingabangeli isifo uma likhona ngamanani amancane. Kodwa-ke, lapho i-bacterium evelele yesitho sangasese sowesifazane i-Lactobacilli incishisiwe noma iqedwa, okubangela ukungalingani endaweni yangasese, i-Gardnerella vaginalis iphindaphindeka ngamanani amakhulu, okuholela ku-bacterial vaginosis. Ngesikhathi esifanayo, amanye amagciwane (afana ne-Candida, i-Neisseria gonorrhoeae, i-Chlamydia trachomatis, njll.) kungenzeka ukuthi ahlasele umzimba womuntu, abangele i-vaginitis exubile kanye ne-cervicitis. Uma i-vaginitis ne-cervicitis ingatholakali futhi yelashwa ngesikhathi nangendlela ephumelelayo, kungase kube khona izifo ezikhulayo zamagciwane eduze kwe-mucosa yepheshana lokuzala, okuholela kalula ezifweni eziphezulu zokuzala ezifana ne-endometritis, i-salpingitis, i-tubo-ovarian abscess (TOA), kanye ne-pelvic peritonitis, okungaholela ngisho nasekukhulelweni okungathí sina. imiphumela.
Imingcele Yezobuchwepheshe
Isitoreji | -18℃ |
Impilo yeshelufu | Izinyanga ezingu-12 |
Uhlobo Lwesifanekiso | ama-swabs owesilisa, ama-swabs omlomo wesibeletho wesifazane, i-swab yesitho sangasese sowesifazane |
Ct | ≤38 |
CV | <5.0% |
LoD | Amakhophi angu-400/mL |
Izinsimbi Ezisebenzayo | Isebenza ekuthayipheni i-reagent yokuthola i-I:I-Applied Biosystems 7500 Real-Time PCR Systems, I-QuantStudio®5 Amasistimu e-PCR wesikhathi sangempela, I-SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.), I-LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, ubuchwepheshe be-Hangzhou Bioer), I-MA-6000 Real-Time Quantitative Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), I-BioRad CFX96 Real-Time PCR System, I-BioRad CFX Opus 96 Real-Time PCR System. Isebenza ohlotsheni lwe-II yokutholwa kwe-reagent: EudemonTMI-AIO800 (HWTS-EQ007) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Ukugeleza komsebenzi
I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kanye ne-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-17u-80 esetshenziswa)TM I-AIO800 (HWTS-EQ007)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Ivolumu yesampula ekhishiwe ingu-200μL futhi ivolumu ye-lution enconyiwe ingu-150μL.