I-Human Papillomavirus (Izinhlobo ezingama-28) I-Genotyping

Incazelo emfushane:

Le kit isetshenziselwa ukutholwa kwekhwalithi kanye ne-genotyping ye-nucleic acid yezinhlobo ezingama-28 ze-human papillomavirus (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52 , 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) kumchamo wesilisa/wesifazane kanye namaseli akhishwe wesibeletho sowesifazane, ahlinzeka ngezindlela ezisizayo zokuxilongwa nokwelashwa kwe-HPV.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-CC013-Human Papillomavirus (Izinhlobo ezingama-28) I-Genotyping Detection Kit (i-Fluorescence PCR)

I-Epidemiology

Umdlavuza womlomo wesibeletho ungesinye sezimila eziyingozi ezivame kakhulu emgudwini wokuzala wabesifazane.Ucwaningo lwangaphambilini lubonise ukuthi ukutheleleka okuqhubekayo kanye nokutheleleka okuningi kwe-human papillomavirus kungenye yezimbangela ezibalulekile zomdlavuza womlomo wesibeletho.Njengamanje, kusenokuntuleka kwezindlela zokwelapha ezisebenzayo ze-HPV, ngakho ukutholakala kusenesikhathi kanye nokuvimbela kusenesikhathi kwe-HPV yomlomo wesibeletho yizihluthulelo zokuvimba umdlavuza.Ukusungula indlela elula, eqondile futhi esheshayo yokuxilongwa kwe-etiological ibaluleke kakhulu ekuxilongweni komtholampilo komdlavuza womlomo wesibeletho.

Isiteshi

Isilondolozi sokusabela FAM VIC/HEX I-ROX CY5
I-HPV Genotyping Reaction Buffer 1 16 18 / Ukulawula kwangaphakathi
I-HPV Genotyping Reaction Buffer 2 56 / 31 Ukulawula kwangaphakathi
I-HPV Genotyping Reaction Buffer 3 58 33 66 35
I-HPV Genotyping Reaction Buffer 4 53 51 52 45
I-HPV Genotyping Reaction Buffer 5 73 59 39 68
I-HPV Genotyping Reaction Buffer 6 6 11 83 54
I-HPV Genotyping Reaction Buffer 7 26 44 61 81
I-HPV Genotyping Reaction Buffer 8 40 43 42 82

Imingcele Yezobuchwepheshe

Isitoreji Uketshezi: ≤-18℃
Impilo yeshelufu Izinyanga ezingu-12
Uhlobo lwesifanekiso I-Cervical Swab, I-Vaginal Swab, Umchamo
Ct ≤28
CV ≤5.0%
LoD 300Amakhophi/mL
ukucacisa Yonke imiphumela iba mibi uma ikhithi isetshenziselwa ukuthola ama-specimens angaqondile anokusabela okuphambene nayo, okuhlanganisa ureaplasma urealyticum, chlamydia trachomatis of reproductive tract, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, isikhunta, i-gardnerella nezinye izinhlobo ze-HPV ezingamboziwe. ngekhithi.
Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR System

Applied Biosystems 7500 Fast Real-Time PCR Systems

I-QuantStudio®5 Izinhlelo ze-PCR Zesikhathi Sangempela

SLAN-96P Real-Time PCR Systems

I-LightCycler®480 Real-Time PCR Systems

LineGene 9600 Plus Real-Time PCR Detection Systems

I-MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Ukugeleza komsebenzi

Inketho 1.

Ama-reagents okukhipha anconyiwe: I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8)

Inketho yesi-2.

Ama-reagents okukhipha anconyiwe: I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) kanye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS- 3006B)