SARS-CoV-2/influenza A /influenza B

Incazelo emfushane:

Le kit ilungele ukutholwa kwe-in vitro qualitative ye-SARS-CoV-2, umkhuhlane A kanye ne-influenza B nucleic acid ye-nasopharyngeal swab kanye namasampula e-oropharyngeal swab ukuthi yibaphi abantu okusolwa ukuthi banegciwane le-SARS-CoV-2, umkhuhlane A kanye nomkhuhlane. B. Ingasetshenziswa futhi ezimweni ezisolekayo zenyumoniya kanye nezimo ezisolekayo ze-cluster kanye nokutholwa kwekhwalithi nokuhlonza i-SARS-CoV-2, umkhuhlane A kanye ne-influenza B nucleic acid ku-nasopharyngeal swab kanye namasampula e-oropharyngeal swab yenoveli ye-Coronavirus kwezinye izimo.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

HWTS-RT148-SARS-CoV-2/influenza A /influenza B Nucleic Acid Combined Detection Kit (Fluorescence PCR)

Isiteshi

Igama lesiteshi I-PCR-Mix 1 I-PCR-Mix 2
Isiteshi se-FAM I-ORF1ab yofuzo IVA
Isiteshi se-VIC/HEX Ukulawula kwangaphakathi Ukulawula kwangaphakathi
Isiteshi se-CY5 I-N isakhi /
Isiteshi se-ROX E gene IVB

Imingcele Yezobuchwepheshe

Isitoreji

-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso i-nasopharyngeal swabs kanye ne-oropharyngeal swabs
Ithagethi Izinhloso ezintathu ze-SARS-CoV-2 (izakhi zofuzo ze-Orf1ab, N kanye no-E)/umkhuhlane A /umkhuhlane B
Ct ≤38
CV ≤10.0%
LoD I-SARS-CoV-2:300 Amakhophi/mL

igciwane lomkhuhlane A:500 Amakhophi/mL

igciwane lomkhuhlane B:500 Amakhophi/mL

Ukucaciswa a) Imiphumela yokuhlolwa kwesiphambano ibonise ukuthi ikhithi iyahambisana ne-coronavirus yabantu i-SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, i-respiratory syncytial virus A no-B, parainfluenza virus 1, 2 no-3, i-rhinovirusA, B no-C, i-adenovirus 1, 2, 3, 4, 5, 7 kanye no-55, i-metapneumovirus yabantu, i-enterovirus A, B, C no-D, igciwane le-human cytoplasmic pulmonary virus, i-EB virus, igciwane lesimungumungwane I-cytomegalovirus yabantu, i-rotavirus, i-norovirus, igciwane le-mumps, i-varicella zoster virus, i-Mycoplasma pneumoniae, i-Chlamydia pneumoniae, i-Legionella, i-pertussis, i-Haemophilus influenzae, i-Staphylococcus aureus, i-Streptococcus pneumoniae, i-Streptococcus pyogenes, i-Klebsiella pneumoniaeberculos, i-Casbacterium fucoccus, i-Mycobacterium fucoccus ta Kwakungekho ukusabela okuphambene phakathi kwe-Pneumocystis yersini kanye ne-Cryptococcus neoformans.

b) Amandla okunqanda ukuphazamiseka: khetha i-mucin (60mg/mL), 10% (V/V) igazi lomuntu, i-diphenylephrine (2mg/mL), i-hydroxymethylzoline (2mg/mL), i-sodium chloride (equkethe isilondolozi) (20mg/mL), i-beclomethasone (20mg/mL), i-dexamethasone (20mg/mL), i-flunisone (20μg/mL), i-triamcinolone acetonide (2mg/mL), i-budesonide (2mg/mL), i-mometasone (2mg/mL), i-fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL) ), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) kanye tobramycin (0.6mg/mL) .Imiphumela yabonisa ukuthi izinto eziphazamisayo ekugxilweni okungenhla zazingenayo impendulo yokuphazamiseka emiphumeleni yokutholwa kwamagciwane.

Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR Systems

I-SLAN ®-96P Real-Time PCR Systems

I-QuantStudio™ 5 Real-Time PCR Systems

I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela

I-LineGene 9600 Plus Real-Time PCR Detection System

I-MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Isixazululo se-PCR esiphelele