SARS-CoV-2/influenza A /influenza B

Incazelo emfushane:

Le khithi ifanele ukutholwa kwe-in vitro qualitative ye-SARS-CoV-2, umkhuhlane A kanye ne-influenza B nucleic acid ye-nasopharyngeal swab kanye namasampula e-oropharyngeal swab ukuthi yibaphi kubantu okusolakala ukuthi banegciwane le-SARS-CoV-2, umkhuhlane A kanye nomkhuhlane B. Ingaphinda isetshenziswe ezimweni ezisolisayo ze-cqualita pneumonia nokusolakala ukuthi bane-cqualita I-SARS-CoV-2, umkhuhlane A kanye ne-influenza B nucleic acid ku-nasopharyngeal swab kanye namasampula e-oropharyngeal swab okutheleleka kwe-coronavirus yenoveli kwezinye izimo.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

HWTS-RT148-SARS-CoV-2/influenza A /influenza B Nucleic Acid Combined Detection Kit (Fluorescence PCR)

Isiteshi

Igama lesiteshi I-PCR-Mix 1 I-PCR-Mix 2
Isiteshi se-FAM I-ORF1ab yofuzo IVA
Isiteshi se-VIC/HEX Ukulawula kwangaphakathi Ukulawula kwangaphakathi
Isiteshi se-CY5 I-N isakhi /
Isiteshi se-ROX E gene IVB

Imingcele Yezobuchwepheshe

Isitoreji

-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso i-nasopharyngeal swabs kanye ne-oropharyngeal swabs
Ithagethi Izinhloso ezintathu ze-SARS-CoV-2 (izakhi zofuzo ze-Orf1ab, N kanye no-E)/umkhuhlane A /umkhuhlane B
Ct ≤38
CV ≤10.0%
LoD I-SARS-CoV-2:300 Amakhophi/mL

igciwane lomkhuhlane A:500 Amakhophi/mL

igciwane lomkhuhlane B:500 Amakhophi/mL

Ukucaciswa a) Imiphumela yokuhlolwa kwesiphambano ikhombise ukuthi ikhithi iyahambisana ne-coronavirus yabantu i-SARSr- CoV, i-MERSr-CoV, i-HcoV-OC43, i-HcoV-229E, i-HcoV-HKU1, i-HCoV-NL63, i-respiratory syncytial virus A no-B, i-parainfluenza virus 1, 2 kanye no-3, i-rhinovirus, i-C3, i-Adenovirus, i-Adenovirus I-5, 7 kanye ne-55, i-metapneumovirus yomuntu, i-enterovirus A, B, C no-D, igciwane le-cytoplasmic pulmonary virus, igciwane le-EB, igciwane lesimungumungwane I-cytomegalovirus yabantu, i-rotavirus, i-norovirus, i-mumps virus, i-varicella zoster virus, i-Mycoplasma pneumoniae, i-Chlamydia pneumoniaetus, i-Staphylocomocus, i-Legionella, i-Haenophilia aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergillus fumigatus, Candida albicans, Candida glabrata Akukho ukusabela okuphambene phakathi kwe-Pneumocystis yersini ne-Cryptococcus neoformans.

b) Ikhono lokunqanda ukugxambukela: khetha i-mucin (60mg/mL), 10% (V/V) igazi lomuntu, i-diphenylephrine (2mg/mL), i-hydroxymethylzoline (2mg/mL), i-sodium chloride (equkethe isilondolozi) (20mg/mL), i-beclomethasone (20mg/mL), i-dexamesomg/mL), i-dexamesomg/mL (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), i-fluticasone (2mg/mL), i-histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL), i-rinomimg/0mg/1mg, i-zanamivir i-oseltamivir (60ng/mL), i-pramivir (1mg/mL), i-lopinavir (500mg/mL), i-ritonavir (60mg/mL), i-mupirocin (20mg/mL), i-azithromycin (1mg/mL), i-ceprotene (40μg/mL) i-Meropenem (200mg/mfloxan/mL) (0.6mg/mL). Imiphumela yabonisa ukuthi izinto eziphazamisayo ekugxilweni okungenhla zazingenayo impendulo yokuphazamiseka emiphumeleni yokutholwa kwamagciwane.

Izinsimbi Ezisebenzayo I-Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR Systems

I-SLAN ®-96P Real-Time PCR Systems

I-QuantStudio™ 5 Real-Time PCR Systems

I-LightCycler®480 uhlelo lwe-PCR yesikhathi sangempela

LineGene 9600 Plus Real-Time PCR Uhlelo Lokuthola

I-MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Real-Time PCR System

I-BioRad CFX Opus 96 Real-Time PCR System

Isixazululo se-PCR esiphelele

ukuhamba komsebenzi

  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona