I-Yersinia Pestis Nucleic Acid

Incazelo emfushane:

Le kit isetshenziselwa ukutholwa kwekhwalithi ye-Yersinia pestis nucleic acid kumasampula egazi.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-OT014-Yersinia Pestis Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

I-Yersinia pestis, evame ukubizwa ngokuthi i-Yersinia pestis, izala ngokushesha futhi ine-virulence ephezulu, okuyibhaktheriya ye-pathogenic evamile yesifo phakathi kwamagundane kanye nesifo phakathi kwabantu. Kunezindlela ezintathu eziyinhloko zokutheleleka: ① ukutheleleka ngesikhumba: ukutheleleka ngesikhumba esonakele kanye nolwelwesi lwamafinyila ngenxa yokuthinta isikhwehlela nobomvu besiguli obunamagciwane, noma ngesikhumba sesilwane, igazi, inyama, kanye nendle yamazeze esifo; ②ukudluliselwa ngomgudu wokugaya ukudla: ukutheleleka ngomgudu wokugaya ukudla ngenxa yokudla izilwane ezingcolile; ③Ukudluliselwa ngomgudu wokuphefumula: isikhwehlela esinamagciwane, amaconsi noma uthuli olusakazeka ngamaconsi okuphefumula, kubangela ubhubhane phakathi kwabantu. Kube khona izifo eziwumshayabhuqe ezintathu ezinkulu zesifo emlandweni wesintu, esokuqala kwaba “Isifo sikaJustinian” ekhulwini lesi-6; kwalandelwa "Ukufa Okumnyama" okwabulala cishe ingxenye eyodwa/3 yabantu baseYurophu ngekhulu le-14; ubhubhane lwesithathu lwaqala eSifundazweni saseYunnan, eChina ngekhulu le-19, lwabe selukhukhula lwanqamula eningizimu yeChina lwasakazekela eHong Kong ngisho nasemhlabeni wonke. Phakathi nalezi zifo eziwubhadane ezintathu, abantu abangaphezu kwezigidi eziyi-100 balahlekelwa izimpilo zabo.

Imingcele Yezobuchwepheshe

Isitoreji

-18℃

Impilo yeshelufu Izinyanga ezingu-12
Uhlobo Lwesifanekiso I-swab yomphimbo
CV ≤5.0%
LoD 500 Amakhophi/μL
Izinsimbi Ezisebenzayo Isebenza ekuthayipheni i-reagent yokuthola i-I:

I-Applied Biosystems 7500 Real-Time PCR Systems,

I-QuantStudio®5 Amasistimu e-PCR wesikhathi sangempela,

I-SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.),

I-LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, ubuchwepheshe be-Hangzhou Bioer),

I-MA-6000 Real-Time Quantitative Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

I-BioRad CFX96 Real-Time PCR System,

I-BioRad CFX Opus 96 Real-Time PCR System.

Kusebenza kuhlobo lwe-II esebenzayo yokuthola:

EudemonTMI-AIO800 (HWTS-EQ007) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ukugeleza komsebenzi

I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. ingasetshenziswa ne-Auto Macro & Micro-T. (HWTS-3006C, HWTS-3006B). Ukukhipha kufanele kwenziwe ngokuvumelana nomyalelo wokusetshenziswa. Ivolumu ye-elution enconyiwe ngu-80μL.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona