I-chlamydia trachomatis nucleic acid

Incazelo emfushane:

Le kit isetshenziselwa ukutholwa okuvela ku-chlamydia trachomatis nucleic acid emchameni wesilisa, amasampula wesilisa wesilisa, kanye namasampula wesibeletho sowesifazane.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama lomkhiqizo

I-HWTS-UR001A-CHEMMYDIA TRACHOZIT NUCLEIC Acid Detection Kit (Fluorescence PCR)

Ukusetshenziswa okuhlosiwe

Le kit isetshenziselwa ukutholwa okuvela ku-chlamydia trachomatis nucleic acid emchameni wesilisa, amasampula wesilisa wesilisa, kanye namasampula wesibeletho sowesifazane.

I-Epidemiology

I-Chlamydia Trachomatis (CT) uhlobo lwe-prokaryotic microorganism oluhambisana ngokuqinile emangqamuzaneni e-eukaryotic. I-Chlamydia Trachomatis ihlukaniswe ngama-ak serotypes ngokuya ngendlela ye-serotype. Ukutheleleka kwe-Urogenital tract kudalwa kakhulu yi-trachoma biological varetros ehlukile ye-sperotypes, futhi abesilisa babonakaliswa kakhulu njenge-urethritis, engakhululwa ngaphandle kokwelashwa, kepha iningi labo liba yi-epidedymitis, i-proctitis, njll. Izinsikazi kungabangelwa nge-urethritis, i-cervicitis, njll., kanye nezinkinga ezinkulu kakhulu ze salpititis.

I-Epidemiology

I-FAM: Chlamydia Trachomatis (CT) ·

I-VIC (Hex): Ukulawulwa Kwangaphakathi

Izimo ze-PCR zokumenyezelwa

Gxatha

Imijikelezo

Izinga lokushisa nokubanda

Isikhathi

Qoqa amasiginali we-fluorescent noma cha

1

1 Umjikelezo

50 ℃

5mins

No

2

1 Umjikelezo

95 ℃

10mins

No

3

Imijikelezo engama-40

95 ℃

15 sects

No

4

58 ℃

Amasekhondi angama-31

Yebo

Amapharamitha Ezobuchwepheshe

Ukubeka

 ≤-18 ℃ ebumnyameni

Ishalofu-impilo

Izinyanga eziyi-12

Uhlobo lwe-Specimen Okwethukile kwabesilisa urethral, ​​ama-secreints wesibeletho wesifazane, umchamo wesilisa
Ct

≤38

CV <5.0%
Indlu edayisa insimbi 400copies / ml
Ukucacisa

Akukho ukubhebhana kokuphindaphinda kokuthola amanye amagciwane atheleleke nge-STD atheleleke ngale kit, njenge-treanema pallidum, i-ureaplasma ureatis, i-mycoplasma hominis, i-mycoplasma hominis, i-mycoplasma geninis, okungaphandle kwebanga lokutholwa kwekhithi.

Izinsimbi ezisebenzayo

Ingaqondanisa amathuluzi we-PCR e-PCR eseMakethe emakethe.

Kusetshenziswe ama-biosystems 7500 real-time PCREMS

Kusetshenziswe ama-biosystem 7500 ngokushesha amasistimu we-real-time PCR

I-QuantStudio®Amasistimu we-PCR e-Real-time real

SLAN-96P real-time PCRS Systems

I-Lightcycler®480 Uhlelo lwe-PCR lwe-Real-time real

I-LineGene 9600 Plus Real-Time Pcc Retection System

I-MA-6000 I-CYRLE YOKUQHAWULA YOKUQALA

I-Biorad CFX96 Uhlelo lwe-Real-Time PCR

Biorad cfx opus 96 uhlelo lwe-real-time PCR

Ukugeleza komsebenzi

002EA7CCF143E4C0E7Ab60a40b9e481


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha bese usithumela kithi