Ikhithi Yokuthola I-STI Multiplex 7

Incazelo emfushane:

Ikhodi Yomkhiqizo

I-HWTS-UR012

Ukusetshenziswa Okuhlosiwe

Le khithi ihloselwe ukuthola izifo ezivamile zezifo ze-urogenital, okuhlanganisa i-Neisseria gonorrhoeae (NG), i-Chlamydia trachomatis (CT), i-Ureaplasma urealyticum (UU), i-Herpes Simplex Virus Type 1 (HSV1), i-Herpes Simplex Virus Type 2 (HSV2), i-Mycoplasma hominis (Mh), i-Mycoplasma genitalium (Mg) kumasampula okukhishwa komgudu womchamo wabesilisa kanye nowesifazane.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Igama Lomkhiqizo

Ikhithi Yokuthola I-STI Multiplex

I-Epidemiology

Izifo ezithathelwana ngocansi (STI) ziseyinye yezinsongo ezinkulu ekuphepheni kwempilo yomphakathi emhlabeni wonke, okungaholela ekungazalini, ekuzalweni ngaphambi kwesikhathi, ekuveleni kwe-tumor, kanye nezinkinga eziningi ezinkulu. Kunezinhlobo eziningi zamagciwane e-STI, okuhlanganisa amagciwane, amagciwane, i-chlamydia, i-mycoplasma, kanye nama-spirochetes. I-NG, i-CT, i-UU, i-HSV 1, i-HSV 2, i-Mh, i-Mg zivame kakhulu.

Amapharamitha Obuchwepheshe

Isitoreji ≤ -18℃
Isikhathi sokuphelelwa yisikhathi Izinyanga ezingu-12
Uhlobo Lwesifanekiso Ukukhishelwa komchamo, Ukukhishelwa komlomo wesibeletho
CV <5.0%
I-LoD Umkhawulo Wokuthola (LoD): I-LoD yekhithi yokuthola i-CT, NG, UU, HSV1, HSV2 kanye ne-Mg ingamakhophi angu-400/mL; i-LoD yekhithi yokuthola i-Mh ingamakhophi angu-1000/mL.
Ukucaciswa Akukho ukusabela okuhlangene nezifo ezifanayo ze-STI.
Izinsimbi Ezisebenzayo

Izinhlelo ze-Applied Biosystems 7500 Real-Time PCR, Izinhlelo ze-Applied Biosystems 7500 Fast Real-Time PCR, Izinhlelo ze-QuantStudio®5 Real-Time PCR, Izinhlelo ze-SLAN® -96P Real-Time PCR, Uhlelo lwe-LightCycler® 480 Real-Time PCR, Uhlelo lwe-LineGene 9600 Plus Real-Time PCR Detection (FQD-96A, ubuchwepheshe be-Hangzhou Bioer), i-MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), i-BioRad CFX96 Real-Time PCR System, i-BioRad CFX Opus 96 Real-Time PCR Systemand njll.

Isiteshi

I-Reaction Buffer Ithagethi Intatheli Isicimi
I-STI Reaction Buffer 1 CT I-FAM akukho
UU I-VIC(HEX) akukho
Mh I-ROX akukho
I-HSV1 CY5 akukho
I-STI Reaction Buffer 2 NG I-FAM akukho
I-HSV2 I-VIC(HEX) akukho
Mg I-ROX akukho
IC CY5 akukho

Ukugeleza Komsebenzi

670e945511776ae647729effe7ec6fa

Ama-reagent adinga kodwa awanikezwa

I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8); I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3017) (engasetshenziswa ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhishwa kufanele kwenziwe ngokwe-IFU.

Izinto ezisetshenziswayo zidinga kodwa azinikezwa:I-1.5mL yeshubhu ye-centrifuge engena-DNase/RNase, Amathiphu angenayo i-DNase/RNase, i-entrifuge yedeskithophu, i-desktop oscillation mixer.


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi